Full Setting The System
The full setting procedure can be initiated from any remote keypad (if more than one is
fitted). Before attempting to full set the alarm system ensure that all movement detectors
are unobstructed and all doors, and windows are secure.
SYSTEM OPEN
17:30
01 Jan
Press ENT to
Select Functions
Please Exit Now.
Time left > 0035
SYSTEM SET
17:31
01 JAN
? ? ? ?
LCD Remote
1
2
Starburst Remote
? ? ? ?
LED Remote
? ? ? ?
OPEN
Func.
0035
SET
3
1
2
3
1
2
3
1.
From the unset (open) mode enter your passcode.
2.
After 5 seconds the exit sounder will start and the display will show the remaining exit
time.
3.
Leave the premises by the designated exit route, close the final door and press the
exit terminator button (if fitted). The system is fully set when the exit sounder stops.
�
To abandon the setting process any time, simply re-enter your passcode.
�
If the display shows “9999" at step 2 the system is configured set by exit
terminator or on closure of the last exit circuit.
NOTES
�
If an attempt is made to full set the system whilst one or more circuits are
active (such as a door being open) the display at step (2) will indicate the
circuit(s) that are in fault and internal sounder generates an interrupted
tone. The fault must be cleared before the setting procedure can be
completed. If the fault is still present at the end of the exit time an internal
alarm will be generated. If fitted, the external strobe light will flash indicating
that the system has “Failed to set”. To prevent this alarm simply re-enter your
passcode before the exit timer expires.
7