FOCKE MELER GLUING SOLUTIONS
INSTALLATION
3-4
Warning:
Risk of electrical shock. Carelessness may cause injury or death.
Install the electrical wall bushing M50x1.5mm in the area reserved for them,
fastening them to the plate with the appropriate nut.
Open the electric cabinet door as far as possible. Thread the power cord (Ø30-
38mm) through the electrical wall bushing M50x1.5mm and fasten it to the
inside anchor, making sure that the cord reaches the power terminals bolck
inside the cabinet.
Connect each wire in the power cord to its corresponding place on the power
terminals block, as shown in the figures.
The Macro 200 melter needs a 5x25mm
2
connection.
Pneumatic connection
If a pneumatically controlled by-pass pressure control valve is installed, the
equipment must have a compressed air supply.
Before connecting the pneumatic power to the melter, make sure the pressure
regulator is completely closed. To do this, turn the regulator located on the
front of the equipment next to the pressure gauge counterclockwise as far as
it will go.
Connect the plant air supply (max. 6 bar) to the melter intake using flexible
tubing with an outside diameter of 6mm. The equipment is provided with a
quick coupling for this purpose.
Activate the air supply to pass and turn the pressure regulator clockwise.
The ratio between the pneumatic pressure and the hydraulic pressure on the
circuit is 1 to 13 bar.
Warning:
A 6 bar on the grid, the maximum pressure on the hydraulic circuit
reaches 80 bar. There is a risk of burns or particle projection. Use thermal
protective clothing and goggles.
Equipment
No. Outputs
3 Phases, 400 VAC Y. 1 single pump
Macro 200
2
56.6 A
R
R
SS
TT
N
N
L1 L2 L3 N PE
3N ~ 400V 50/60Hz + PE
Summary of Contents for MACRO 200
Page 1: ...ADHESIVE MELTER MACRO 200 INSTRUCTIONS MANUAL MA 5068 ENG 221220 GLUING SOLUTIONS ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5068 ENG MACRO 200 INSTRUCTIONS MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...