A-5
PROFIBUS CONNECTION
MA-5068-E
MACRO 200 INSTRUCTIONS MANUAL
Memory table description
Byte: Configuration – Read
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Level Hot-Melt
State
Front Panel
Temp. Ok signal
Activated
Temp. OK signal
waiting
bit 7 : Define the state of the hot-melt low level detection
“ 0 “ : Hot-melt level OK
“ 1 “ : Hot-melt level low
bit 6 : Define the state of the front panel
“ 0 “ : Front panel activated
“ 1 “ : Front panel deactivated
bit 2,3,4,5 : No function
bit 1 : Define the state of the temperature OK signal
“ 0 “ : Temperature OK
“ 1 “ : Temperature NO OK
bit 0 : Define the state of the delay timer in the temperature OK signal
“ 0 “ : It`s not temporizing
“ 1 “ : It`s temporizing
Byte: Configuration- Read/Write
bit 7 : No function
bit 6 : Define the state of the hot-melt low level alarm
“ 0 “ : Low level detection OFF
“ 1 “ : Low level detection ON
bit 5 : Define the state of the Activate/Deactivate Programming
“ 0 “ : Activ/Deactiv Programming OFF
(not allowed )
“ 1 “ : Activ/Deactiv Programming ON
(allowed)
bit 4 : Define the state of the Standby Programming
“ 0 “ : Standby Programming OFF (not allowed )
“ 1 “ : Standby Programming ON (allowed)
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Alarm hot-melt-
low level
Programming
ON/OFF
Programming
Standby
Motor ON
Temperature
units
Standby
ON/OFF
Summary of Contents for MACRO 200
Page 1: ...ADHESIVE MELTER MACRO 200 INSTRUCTIONS MANUAL MA 5068 ENG 221220 GLUING SOLUTIONS ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5068 ENG MACRO 200 INSTRUCTIONS MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...