MELER GLUING SOLUTIONS
4-10
MELTER OPERATION
4. The blinking dot next to the start time indicates that this is the value
that may be modified. Use the up-down arrow to select the desired
value.
5. Press the button with the clock symbol once again.
The dot changes to the finish time.
6. Use the up-down arrow to select the desired value.
7. Press the button with the clock symbol once again.
The selected program will appear once again. Use the up-down arrow
to select other programs.
8. Pressing either the left or the right arrow button will exit this program
and return to the tank temperature display.
The green LED next to the ‘ON/OFF’ button will remain blinking as long as
there is an equipment disconnection time programmed for the current day.
Disabling the equipment activation/deactivation program
It is possible to disable the equipment activation/deactivation programming
without canceling the daily programming. This way the programmed data is
saved, but the programming will have no effect on the equipment.
1. Press the button with the clock symbol.
A ‘0’ will appear on the display, indicating the program for current day
and hour information.
2. Use the up-down arrow to go past the selection for the last day of the
week (7).
The message ‘ON/OFF’ will appear on the display, depending on the
current status.
3. Press the button with the clock symbol once again.
The status will alternate each time you press the button.
4. Pressing either the left or the right arrow button will exit this program
and return to the tank temperature display.
1 6 0
1 6 0
1 6 0
1 6 0
1 6 0
1 6 0
1 6 0
1 6 0
2
2
1 9 . 3
1 9 . 3
0 7 . 2
0 7 . 2
0
0
o f f
o f f
Summary of Contents for MACRO 200
Page 1: ...ADHESIVE MELTER MACRO 200 INSTRUCTIONS MANUAL MA 5068 ENG 221220 GLUING SOLUTIONS ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5068 ENG MACRO 200 INSTRUCTIONS MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...