45 / 62
9750359
Read/modify settings (
service code 10001
)
The user can carry out all functions required for normal operation and configure the
settings.
Authorisation level 4
– extended configuration level
Read settings (
service code: 40000
)
The user can view the extended settings.
Read/modify settings (
service code 40044
)
In addition to the functions and settings for authorisation level 1, the operator can
view/edit all the relevant parameters for the dosing equipment. The i-menu shows all
variable parameters in the corresponding tabs (dosing system, wash programs).
Note
Certain menu functions in i-menu and the action menu have to be enabled by an
authorised service technician before the operator can use them (reset counter,
etc.).
i-menu
Symbol Level Description
Languages
1, 4
Set display language
Hood movement
1, 4
Lift/lower hood and view status
Wash tank
1, 4
Set automatic hood opening and descaling parameters
View status
Final rinse
1, 4
View status
Chemicals
1
Set dosage quantity for detergent and rinse aid
Water treatment
1
Set degree of hardness and treatment parameters
Heat recovery
1
No user settings
Energy optimisation
1, 4
No user settings
Global
1
Set wash programme channels and Bluetooth communication
Operational times
1,4
View batches, operational times, etc.
Daily protocol
1,4
View archived operational times, events, etc.
Wash programmes
4
Set quantity of rinse aid and fine tune dosing
Settings
1,4
Set date/time, reset counter, notification settings
General
1,4
View software version, machine serial number, machine type
Dosing system
4
Dosing parameters for the dosing technician
Summary of Contents for M-iClean H series
Page 61: ...61 62 9750359 13 Notes...