9750359
20 / 62
• The rinsing process runs until the end of the programme cycle time, but at least
until the temperature value and specified stop time are reached. After this
comes a pause for draining, final rinse and a subsequent application time.
Thermolabel and thermal disinfection control offer a disinfection effect that exceeds
the standard, such as for hospitals, care homes, requirements according to the
ÖGSV Guideline.
4.7.6
Heat retention
The heat retention setting closes the back of the hood when the hood is open.
• Loss of steam into the surrounding area at the end of the cycle is reduced.
• Saves energy by retaining steam.
Available:
• ONLY in conjunction with automatic hood system
• NOT in conjunction with AirConcept
4.7.7
Exhaust heat recovery (AirConcept)
The exhaust heat recovery system is installed on the back of the hood:
• Loss of steam into the surrounding area is reduced.
• Saves energy by targeted suction of hot steam through a fresh water heat ex-
changer.
• Heated water is available for the next wash cycle.
Available:
• NOT in conjunction with warm water
• NOT in conjunction with heat retention
4.7.8
Wastewater heat recovery
Hot wastewater is pumped through a metal pipe into a stainless steel heat ex-
changer:
• The fresh water in the metal chamber of the heat exchanger is heated.
• Saves energy because the boiler can heat less.
4.8
Automatic standard functions
4.8.1
Eco mode
During periods of inactivity (pauses), the machine displays a leaf symbol to show
that energy is being saved and components protected.
Active
following
Description
ECO MODE I
60 sec Rinse water temperature reduced.
ECO MODE II
180 min
Rinse and wash water temperatures reduced. Water level in wash
tank adjusted to optimum level.
ECO MODE III
8 h
Boiler is drained. Wash water temperature is reduced. Water level in
wash tank adjusted to optimum level.
ECO MODE IV
14 h Machine is drained and shut down.
Summary of Contents for M-iClean H series