41 / 62
9750359
Malfunction
Possible cause
Remedy
Unsuitable rinse aid
Change product
Hood no longer
opens/closes automati-
cally
see chapter “Restricted operation” on page 41
As a rule, faults that are not described here require assistance from an authorised
service technician. Please contact your subsidiary or authorised dealer.
8.4.1
Restricted operation
In case of a malfunction of the automatic hood system, the machine switches to re-
stricted operation. The dishwashing machine can still be used for rinsing, but the
hood must be opened and closed manually as far as it will go. The programme can
only be started via the wash key.
During restricted operation, message 161 is permanently displayed. The cause of
the fault (messages 19, 20, 157, 158 and 160) lies in contradictory or non-existent
signals concerning the upper and lower hood position.
Troubleshooting
Normally, it is sufficient to perform a complete hood drive (open/closed/open) at
moderate speed for calibration. If successful, a message 162 to be acknowledged
may appear, and if the software is newer, a message 163 not to be acknowledged.
The machine then resumes normal operation.
It is also possible to disconnect the machine completely from the power supply (no
emptying is necessary). After initialisation, all functions are available again.
8.4.2
Messages
When a malfunction occurs, a grey or red message is shown on the display depend-
ing on the nature of the malfunction.
• Grey messages can be acknowledged using the relevant confirmation key.
• Red messages usually require the deployment of an authorised service techni-
cian.
- When these messages occur:
• Not possible to continue working
• Switch off on-site power supply
• Close on-site water supply
• Call a service technician!
No.
Display text
Measures/remedial action
6
Programme interrupted prematurely
• Start wash cycle again
11
Carry out maintenance
• Possible to continue working
• Call a service technician!
12
Code entry wrong!
• Enter correct entry code
15
Heat recovery cancellation
• Allow the heat recovery process to run to completion.
1, 100, 102, 104, 107, 108, 109, 110, 150, 201, 203, 204, 206, 207, 208,
209, 330, 420, 425, 427, 880, 901/902, 931-945, 960.
Summary of Contents for M-iClean H series
Page 61: ...61 62 9750359 13 Notes...