15-SAFETY DEVICES
SAFETY DEVICES
The product is fitted with the following safety devices
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down the pellet feed screw in the event of an obstructed flue or significant
back-pressure (from wind).
SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
CONTACT THERMOSTAT IN THE FUEL TANK
If the temperature exceeds the preset safety level, it immediately shuts down the stove.
ELECTRICAL SAFETY
The stove is protected against violent changes in current by a general fuse located in the control panel at the back of the stove. Other fuses
that protect the circuit boards are located on the latter.
SMOKE FAN
If the fan stops, the circuit board immediately shuts off the supply of pellets and an alarm message is displayed.
GEAR MOTOR
If the gear motor stops, the stove will continue to run until the flame goes out due to lack of fuel and until a minimum level of cooling is
reached.
TEMPORARY POWER OUTAGE
When a power outage lasts less than 10’’ the stove returns to its previous operating state. If it is longer, it executes a cooling/re-ignition
cycle.
FAILED IGNITION
If during ignition no flame develops, the stove will go into alarm condition.
TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED
If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for any
damage caused to persons and property. The manufacturer furthermore denies any liability for damage to persons
and property arising from failure to observe all the rules contained in the manual and specifically:
• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and
repairs.
• Do not tamper with the safety devices.
• Do not remove the safety devices.
• Connect the product to an efficient smoke expulsion system.
• First, check that the environment where it is to be installed is properly ventilated.
Only after having removed the cause that triggered the safety system is it possible to start the product again and
therefore restore automatic operation of the probe. This manual will help you understand which anomaly has
occurred, and explain how to operate according to the alarm message displayed on the appliance.