12
14-MENU ITEMS AND OPERATION
• Use the arrow keys to scroll through and select ‘’Components test’’
• Press “menu” to confirm.
• Use the + - keys to select the test to be carried out.
• Press ‘’menu’’ to confirm and ‘’esc’’ to exit.
k - Chimney sweeper function (for maintenance operators only) -
This function can only be activated when the stove is on and power is supplied, and it forces heating operation at parameters P5, with fan
(if present) in V5. Any corrections to the loading/smoke ventilation percentage must be read. This state lasts 20 minutes, the countdown
is displayed on the panel.
The technician can stop this stage at any moment by quickly pressing the on/off key.
Enable the “Chimney sweeper” function as follows:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to confirm.
• Use the arrow keys to scroll through and select ‘’Chimney sweeper function’’
• Press “menu” to confirm.
• Use the + - keys to select “On” (Off by default)
• Press ‘’menu’’ to confirm and ‘’esc’’ to exit.
l - Technical menu
To access the technical menu, you must contact the service centre as it requires a password.
Proceed as follows to access the “technical menu”:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to confirm.
• Use the arrow keys to scroll through and select ‘’Technical menu’’
• Press “menu” to confirm.
• With the + - keys, select “Product Type”, “Service”, “Counter memories”, “Parameters”.
• Press ‘’menu’’ to confirm and ‘’esc’’ to exit.
INFO MENU
• Product type
• Firmware version
• Software info
• Total hours
• No. of start-ups
• Extractor rpm
• Smoke T.
• Heat exchanger voltage
• Feed screw loading
• Flame