BIM 1004/2005/05
Page 17 of 20
www.nord.com
MOTOR OPTIONS & NOMENCLATURE
1. General
NORD offers many options for its motors. The option code will be shown in the motor nomenclature. Below are
the available options
Code Description Code Description
BRE
With Brake
OL
TENV Motor – Without Fan
RG
Brake – Corrosion Protected
OL/H
TENV Motor - Without Fan & Cover
SR
Brake – Dust Protected
RD
Canopy Cover
HL
Brake – Manual Hand Release
RDD
Double Canopy Cover
FHL
Brake – Lockable Manual Release
RLS
Backstop
MIK
Brake – Microswitch
SH
Motor Space Heater
IR
See Brake
BIM1090
Brake – Current Sensing Relay
TF
Thermistor
KD
Condensation Holes
TW
Thermostat
KB
Condensation Holes - Plugged
WE
2
nd
Motor Shaft End
MS
Power Plug Connector
WU
High Slip Rotor
NSD+
NORD Severe Duty Plus Protection
Z
High Inertia Motor Ran
EHBU
Single Phase, Run Capacitor
H
Energy Efficient
EARU
Single Phase, Start Cap/Run Cap
IP66
IP66 Environmental Protection
F
Blower Cooling Fan - 3ph & 1ph
ISO H
Class H Insulation
FC
Blower Cooling Fan - 1ph
EP
Epoxy Dipped Windings
IG
Incremental Encoder
FK
Over Running Clutch
VR
5:1 Constant Torque Rated Motor
VN
10:1 Constant Torque Rated Motor
VW
20:1 Constant Torque Rated Motor
VZ-F
1000+:1 Constant Torque Rated Motor
Table 5. Motor Option Codes
Examples
90SH/4 IG SH
Energy Efficient, 1 Speed, Encoder & Space Heater
100L/4-2 WE RDD
2 speed, 2
nd
Motor Shaft & Double Canopy Cover
132M/4 BRE100 HL IR TW
Brake, Hand Release, Current Sensor & Thermostat
Technical information follows for THERMISTORS, THERMOSTATS, SPACE HEATERS (Table 6), ENCODERS
(Table 7) & BLOWER COOLING FAN (Table 8).
Thermistors (Option TF)
•
Connection Diagram shown on Page 12
•
Three PTC (Positive Temperature Coefficient) temperature sensitive resistors are wired in series
•
One PTC on each phase of the stator winding
•
The leads will be labeled P1 and P2 in the terminal box
•
This unit must be connected to a Motor Control Protection module such as a Kriwan INT69 or a Variable Frequency
Drive with PTC inputs
All wiring must be done by qualified personnel and adhere to all local codes.
WARNING
: Thermistors will automatically reset.
Thermistor Ratings:
Switching temperature 310
°
F(155
°
C)
Maximum operating voltage 2.5 volts
Resistance at 25
°
C less than or equal to 300 Ohms
Response time < 5 seconds
Motor Nomenclature
Motor Motor
Options
100L / 4 BRE 40 …
Frame
Size
No. of
Poles
Brake
Brake
size Nm
Other
Options
Summary of Contents for ChipMaster
Page 1: ...ChipMaster Operation Maintenance Manual ...
Page 35: ...ChipMaster Conveyor Operation Maintenance Manual 35 Rev 05 2021 Notes ...
Page 41: ...Mat Nr 605 06 99 46 05 www nord com ...
Page 43: ...BIM 1004 2005 05 Page 2 of 20 www nord com NOTES ...
Page 62: ... NOTES ...
Page 63: ... NOTES ...