1
• Periodic inspections should be performed. Failure to perform proper maintenance
can result in premature product failure and personal injury.
• All electrical work should be performed by qualified personnel and compliant with
local and national electrical codes.
• Read and follow all instructions carefully.
• Disconnect and lock-out power before installation and maintenance.
Working on or near energized equipment can result in severe injury or death.
• Do not operate equipment without guards in place. Exposed equipment can
result in severe injury or death.
F O R M
TORQUE LIMITER
INSTALLATION & MAINTENANCE
INSTRUCTIONS FOR 250A THRU 700A
4446-004
Revised
November 2009
Emerson Industrial Automation
Power Transmission Solutions
7120 New Buffington Road
Florence, KY 41042
Application Engineering: 800 626 2093
www.emerson-ept.com
D
E
G
A
J
H
A
B
D
E
F
G
J
1. GENERAL
Before assembly, the pressure plates, facings and center member (sprocket, sheave, plate, etc.) should be free of oil, grease, dirt
and rust. The center member should have a 125 micro-inch finish in the bore and a 63 micro-inch finish on the area where the friction
facings rub in order to obtain maximum rated capacity and optimum life from the Torque Limiter.
2. ASSEMBLY
Refer to the appropriate sketch (see below) and assemble on the torque limiter hub the following: (A) Friction facing (B) Bushing
(C) Center member (not shown) (D) Friction facing (E) Pressure plate (F) Spring(s) (G) Pilot plate (500A and 700A models only) (H)
Lockwasher (250A and 350A models only) (J) Adjusting nut.
4. TORQUE SETTING
(A) For the 250A and 350A models: To adjust the Torque
Limiter to carry the required torque, tighten the ad-
justing nut an appropriate amount.
Do not
completely
flatten the disk spring. Check setting per step 5.
3. RUNNING-IN
Torque Limiters should be run-in for the most consistent re-
sults. To run-in, adjust the Torque Limiter to 70-80% of the
maximum single spring capacity and slip the center member
approximately 60 RPM for approximately 4 minutes. (See steps
4 and 5 for setting and checking instructions.)
Torque Limiter Size
250A
350A
500A
700A
Run-In Torque-Lb. Ft.
14-16
38-44
108-125
290-330
Morse is a registered trademark of Borg-Warner Corporation, used herein under exclusive license.
Emerson and Emerson Industrial Automation are trademarks of Emerson Electric Co. or one of its
affiliated companies.
©1998, 2001, 2009 Emerson Power Transmission Corps., All Rights Reserved.
MCIM09026 • Form 4446-004 • Printed in U.S.
Summary of Contents for ChipMaster
Page 1: ...ChipMaster Operation Maintenance Manual ...
Page 35: ...ChipMaster Conveyor Operation Maintenance Manual 35 Rev 05 2021 Notes ...
Page 41: ...Mat Nr 605 06 99 46 05 www nord com ...
Page 43: ...BIM 1004 2005 05 Page 2 of 20 www nord com NOTES ...
Page 62: ... NOTES ...
Page 63: ... NOTES ...