6
SECTION III
PROGRAM SELECTIONS
A. PREPROGRAMMED CYCLES
“A-F” CYCLES
The Phase 7
OPL microprocessor controller (computer) can store in its memory six (6) preprogrammed cycles
(keys “A-F” on the keyboard [touch pad]). This allows the user to have the six (6) most commonly used cycles,
requiring only the push of a single keyboard (touch pad) entry to start the dryer.
“0-40” CYCLES
The Phase 7
OPL microprocessor controller (computer) can store 41 preprogrammed cycles in its numerical
memory. (Use keys “0-9” on the keyboard [touch pad]). This allows the user to have up to 41 customized
programmed cycles that may not be as commonly used as the six (6) “A-F.” These are not one (1) touch entries
to start the dryer like the “A-F.” They are selected by entering the number, which represents the cycle desired
and pressing the “START/ENTER” key to start the cycle.
Both types of the preprogrammed cycles can be set in either the Automatic Drying Mode
(Patent 4,827,627)
,
where the drying cycle will end when the selected dryness level has been reached, or in the Manual Timed
Drying Mode where the dryer will operate for the specific drying time programmed. These cycles can be
programmed in any combination.
Once the heating cycle is completed, the Phase 7 OPL microprocessor controller (computer) then goes into the
Cool Down Cycle where the articles are tumbled at room temperature or a controlled cool down where the dryer
goes into a slow cool down mode for 10 minutes sloping the temperature 10º F (5.5º C) every minute.
When the cooling cycle is completed, the dryer will go into the Wrinkle Guard Cycle. Where the load will be
tumbled without heat for 2 minutes. It will then stop for 2 minutes. This process is repeated until either the doors
are opened, the “STOP” key pressed, or 99 minutes has elapsed, whichever comes first. When Wrinkle Guard
is ended, the display will read “CYCLE DONE.” At this point the dryer is locked out from drying again until the
doors are opened. This will insure that if a cycle has been completed, the operator will attend to it, before
starting another heat cycle.
NOTE:
To enter program mode press clear/stop and the up arrow.
PREPROGRAMMED CYCLE MENU SELECTIONS (CYCLES “A-F” or “0-40”):
1. Automatic Drying Cycle
(Patent No. 4,827,627)
a. The Phase 7 OPL microprocessor controller (computer) can be programmed to reverse or not reverse.
This is done in “DRYER SETUP” parameter.
b. Drying Temperature - Programmable from 160º F to 200º F (71º C to 93º C) in one-degree increments
and preset at 160º F (71º C) for axial.
Summary of Contents for PHASE 7.2
Page 86: ...113162 1 12 23 02 25...