20
SECTION VI
PROGRAMMING INSTRUCTIONS
A. INTRODUCTION TO PROGRAMMING
The various program selections are stored in the Phase 7 OPL microprocessor controller (computer) and are
broken down into five (5) categories:
0. Language (ENGLISH, FRANCAIS, ESPANOL, ITALIANO, and DEUTSCH).
1. System Parameters (Dryer Setup, Display Setup, Cool Down Setup, and Wrinkle Guard Setup).
2. Preprogrammed Cycles (Key “A-F”).
a. This feature allows the operator to have six (6) most commonly used cycle selections awaiting the push
of a single keyboard (touch pad) entry to start the dryer.
3. Preprogrammed Cycles (“0-40”).
a. This feature allows the operator to have an added forty-one (41) preprogrammed cycle selections.
These can be started by selecting the number and pressing the “START/ENTER”
l
key..
4. Default Settings (returns
ALL
the programmable parameters to the default settings).
Both the preprogrammed cycles and the system parameters (programs) have been preprogrammed by the
factory with the parameters shown in
Section VII
of this manual. The various program selections for the
preprogrammed cycles and system parameters are outlined in
Section III
of this manual.
ALL
program changes for the preprogrammed cycles and system parameters (programs) are done through the
keyboard (touch pad) selection keys on the front of the control panel.
ENTERING THE PROGRAMMING MODE:
First, make sure that no cycle is in progress and that the light emitting diode (L.E.D.) display reads “READY,”
then press the “STOP/CLEAR”
O
key
and the “UP ARROW” key together..
This will put you into the
programming mode.
EXITING THE PROGRAMMING MODE:
The “STOP/CLEAR”
O
key will return you to the previous menu level. Continue to press the “STOP/CLEAR”
O
key until you are
ALL
the way out of the Programming Mode.
To alter the programming parameters, the operator will locate the parameter (program) that is to be changed. If
the change is a numerical one (1) (i.e., time and/or temperature), the operator will simply enter the numerical
value desired. If an error is made, press the “STOP/CLEAR”
O
key ONCE, and the incorrect entry that was
made will be
cancelled. Once the entry is made, and the parameter (program) set does not need to be changed,
press the “START/ENTER”
l
key and the Phase 7 OPL microprocessor controller (computer) will advance to
the next program selected.