15
7) Once the Cool Down Cycle is completed the Phase 7 OPL microprocessor controller (computer)
will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for amount set in
Audio Alert On Time). The light emitting diode (L.E.D.) display will read “WRINKLE GUARD.”
The times are fixed at 2 minutes OFF, 2 minutes ON for a maximum time of 99 minutes. These
times are not programmable. During the ON time, the blower (fan) and the basket (tumbler) will
start to rotate (without heat for 2 minutes). The Phase 7 OPL microprocessor controller (computer)
will repeat this process until the Maximum Wrinkle Guard On Time has expired (99 minutes). The
L.E.D. display will then read “CYCLE DONE” and lockout the dryer functions until the doors are
opened. It will then return to “READY.”
2. Manually Loaded Cycles
a. Automatic Drying Cycle
(Patent No. 4,827,627)
1) L.E.D. display reads “READY” (no cycle in progress).
2) Press AUTO key.
3) L.E.D. display will now read ENTER DRY TEMP 160 TO 200. (Defaults to 160° F [71° C]).
Enter the temperature desired (from 160º F to 200º F [71º C to 93º C] in one-degree increments).
I.E., for 180º F (82º C), press key “1,” key “8,” key “0,” and then press the “START/ENTER”
l
key to accept the value.
4) L.E.D. display will now read ENTER DRY LEVEL finishing, dry, and extra dry. Enter the amount
of extraction (dryness level desired). Finishing has the most moisture content to extra dry, which
has little or no moisture content.
5) L.E.D. display will now read “REVERSE MODE” (defaults to ON). The ON/OFF selection can
be toggled with the “UP ARROW” and “DOWN ARROW.” Once selected, press the “START/
ENTER”
l
key to accept selection.
NOTE:
In addition to entering a value by pressing the number keys, the “UP ARROW” and “DOWN
ARROW” can be used to scroll to the number desired or toggle between selections.
6) The dryer will now display “PRESS START.” Press the “START/ENTER”
l
key to start the
dryer. The L.E.D. display will read AUTO DRYING CYCLE, ELAPSED TIME __ MIN. During
the Drying Cycle, the Phase 7 OPL microprocessor controller (computer) is monitoring the moisture
in the load. Once the temperature is above 160º F (71º C), the Cycle Status portion of the L.E.D.
will change from ELAPSED TIME __ MIN to DRYNESS LEVEL__. The display will count
upward until the percentage of extraction programmed is reached.
NOTE:
Press and hold the “UP ARROW” to view the basket (tumbler) temperature at any time.
NOTE:
The dryer can be stopped at any time by pressing the “STOP/CLEAR”
O
key, at this time the
dryer will go into a cycle pause. If the “STOP/CLEAR”
O
key is pressed again at this point,
the cycle that was in progress
will
be
cancelled and returned to the “READY” state.
Summary of Contents for PHASE 7.2
Page 86: ...113162 1 12 23 02 25...