9
F. CYCLE IN PROGRESS TEMPERATURE DISPLAY
While the dryer cycle is in progress, the temperature in the basket (tumbler) can be displayed by pressing and
holding the “UP ARROW” key. The temperature will be displayed in either Fahrenheit (ºF) or Celsius (ºC),
depending on what the system temperature has been set for in “DRYER SETUP.”
G. TEMPERATURE CONVERSION STATUS
Temperature related programs are programmable to be operated in either Fahrenheit (ºF) or Celsius (ºC). The
temperature selection is made in “SYSTEM TEMP.” Programs affected are:
1. Temperature Display Mode
2. Drying Temperatures
3. Cool Down Temperatures
IMPORTANT:
When changing the temperature conversion status from Fahrenheit to Celsius or vice
versa,
ALL
the Temperature Selections and Cool Down Temperatures
will be
changed accordingly. The Phase 7 OPL microprocessor controller (computer)
automatically calculates and converts the temperatures in these programs to the
previously set value. For example, when changing from ºF to ºC, if the
preprogrammed Cycle “A” drying temperature was set for 160º F, the Phase 7 OPL
microprocessor controller (computer) will change to 71º C (+/- [1] one-degree
Celsius).
H. WRINKLE GUARD PROGRAM
This program keeps items wrinkle-free when they are not removed from the dryer promptly at the end of the
drying cycle and/or cooling cycle.
When the drying and cooling cycles are completed, the dryer will shut off, the tone will sound, and the light
emitting diode (L.E.D.) display will read “WRINKLE GUARD.” If the door is not opened or the cycle stopped,
the Phase 7 OPL microprocessor controller (computer) will wait until the Wrinkle Guard Delay Time of 2
minutes has expired, at which time the fan will start and the basket (tumbler) will rotate (without heat) for the
Wrinkle Guard On Time of 2 minutes. The Phase 7 OPL microprocessor controller (computer) will repeat this
process until the Maximum Wrinkle Guard Time of 99 minutes has expired or until the door is opened, or cycle
stopped, whichever comes first. Prior to each ON time, there is a 3-beep warning that the fan and basket
(tumbler) rotation are about to start. The beeps at the end of the Wrinkle Guard Cycle can be programmed to be
ON/OFF. This is done in “WRINKLE GUARD SETUP.”
WRINKLE GUARD PROGRAM SELECTIONS:
1. Wrinkle Guard Audio Alert On/Off
The operator can select to turn on or off the beeps at the end of each Wrinkle Guard Cycle. The amount
of beeps are programmed in “AUDIO ALERT ON TIMES.”