44
Gate disable feature
event history download
This unique
GATE DISABLE
feature is useful when the gated area needs to be secured from
ALL
but emergency and/or autho-
rized vehicle entry. Some examples are:
This unique
EVENT HISTORY
feature has an On Board Diagnostics (OBD)
port to download a simple .txt file to troubleshoot gate operator errors
and to view normal transaction logs. This file will log intermittent
problems with the gate operator that can be difficult to solve. This file
can even be e-mailed to the factory from out in the field at the job site for
additional technical support if necessary.
The event history can store up to 1000 transactions.
The
GATE DISABLE
feature will allow the FIRE DEPT/MAX and
RADIO inputs to operate but nothing else. It helps with some
major security problems that can occur when no one is
available to monitor the property.
“Like NO other Gate Operator in the World”
•
Residential home vacation period.
•
During closed hours of a business.
GATE DISABLE
prevents breaking into
a keypad box and
trying to trigger the
wires to get the gate
to open.
GATE DISABLE
prevents trying to trigger
the exit loop to get the gate to open.
IMPORTANT:
It is
NOT
recommended activating
GATE DISABLE
while persons are present inside the property.
Event type clarificaon:
INFO:
informaonal message only
WARNING:
unusual event but doesn't cause system malfuncon
ERROR:
abnormal event, could cause system malfuncon
ENTRAP:
entrapment detecon event
Event Report:
Fri 07/11/2014 10:59:41
INFO : Cycle Counter
Fri 07/11/2014 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2014 10:59:37
INFO : Radio Input Deacvated
Fri 07/11/2014 10:59:36
INFO : Radio Input Acvated
Fri 07/11/2014 10:58:54
INFO : PRI_MC: Fully Open Posion Learned
Fri 07/11/2014 10:58:53
INFO : SEC_MC: Fully Open Posion Learned
Fri 07/11/2014 10:57:40
INFO : PRI_CIO: Communicaon Established
Fri 07/11/2014 10:57:38
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:57:34
ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Deacvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Acvated
Fri 07/11/2014 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:36
INFO : SEC_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36
INFO : PRI_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
Event History Text Document Sample
USB Flash Drive
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
N
RECORDER
OPEN
MAX
STOP
CLOSE
UL ALARM 12V
ALARM RET
IN US
LE
SWITCH
ON-LINE
OBD PORT
BLACK BOX
phantom options / unique Features
EXIT LOOP
Meta
l
Pl
ate