1
5
Run in-ground
loops conduit to
CONTROL BOX
.
Center
Loop
Safety
Loop
Safety
Loop
Exit
Loop
4 ft
4 ft
4 ft
4 ft
4 ft
4 ft
4 ft
Control Box
1 1/2”
Typical
1/4” Saw Cut
Saw Cut
Backer Rod
Loop Wire
Pavement
Sealant
Illustration not to scale
Side View of
Saw Cut
Loop lead wires are
twisted 6 twists per
foot minimum inside
conduit.
Safety Loops
Are placed on each side of the gate to prevent
the gate from closing on a vehicle in it’s path.
They will stop or reverse the cycling of the
gate while a vehicle is in or near the gate’s
pathway.
Center Loop
Will
ONLY HOLD
the gate in the
Full Open
Position
when a vehicle is on the center loop.
However, it
WILL NOT stop or reverse
the
gate once it starts to close.
Exit Loop
Automatically opens the gate for exiting
vehicles without having to use a radio
transmitter (remote control). The exit loop
can be placed a minimum of 4 feet away from
the safety loop or far enough away from the
gate so it has opened by the time the vehicle
approaches it.
installation
in-ground loops
Outside Property
Inside Property
Matrix 1 Wiring
Safety loops need
to be wired in series.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
T
Lead Wires
SAFETY LOOP
SAFETY LOOP
EXIT LOOP
CENTER LOOP
Outside Property
Inside Property
EXIT
CENTER
SAFETY
Refer to loop maunufacturer’s
instructions to determine specific
loop dimensions.
It is recommended that a
licenced installer perform
this work.
Install in-ground loops to help
protect vehicles from a moving
gate. See pages 25 & 29 for
wiring instructions.
4 ft min.