WARNING
– To reduce the risk of injury or death:
1.
READ AND FOLLOW ALL INSTRUCTIONS.
2.
Never let children operate or play with gate controls. Keep the remote control away from children.
3.
Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4.
Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the
non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the
gate operator properly can increase the risk of injury or death.
5.
Use the emergency release only when the gate is not moving.
6.
KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate
hardware.
7.
The entrance is for vehicles only. Pedestrians must use separate entrance.
8.
SAVE THESE INSTRUCTIONS
UL 325 Class of Operation
- Class I, II, III, IV
Gate Type
- Vehicular Swing Gate
Max Gate Weight / Length
- 2000lbs @ 15 ft or 1500 lbs @ 20 ft
90° Opening Time
- 16 selectable speeds from approximately 11.5 sec to 20 sec depending on the weight and length of gate.
Cycles per Hour AC Input Power
- Continuous
Battery Back-Up Cycles
(Batteries fully charged)
:
- BC-7 Battery Module-7 Amp/Hr Batteries, approximately 450 cycles
- BC-36 Phantom Battery Module-36 Amp/Hr Batteries, approximately 2000 cycles
Input AC Power
- Switchable: 115VAC or 230VAC single phase
Motor
- 24VDC Brushless (equivalent to 1 HP AC motor)
Operating Temperature
- -4°F to 158°F (-20°C to 70°C)
Entrapment Protection:
- UL 325 Type A Inherent (ERD sensor)
- Input for UL 325 Type B1 (photocell) and B2 (sensing edge)
18 3/4”
14 5/8”
12 5/8”
22”
phantom 2000 specifications
important safety information
NOTE:
The number of gate cycles using
ONLY
battery back-up power will vary
depending on the weight of the gate, the gate length, the operating condition of the gate
hardware, temperature and the amount of charge the batteries have at the beginning of
the battery power only operation.