23
MAX MC-100
Motor Controller
ALA
RM
PWR 24
V -
GND -
RS-485 (-) -
RS-4
85 (+)
-
LIM
IT
SWIT
CH
BA
TTER
Y
PA
CK
MOT
OR
INP
UTS
POWER
IN
MOTOR
www
.max.us.com
Powe
r
INPUT
S
MC-100
JO
G
RIGHT
JO
G
LEFT
UL
Entrap
Ma
trix
On Line
ERD
Se
nsiti
vity
Phot
o
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo Cell
GND
Jog R
T
Jog L
T
M
OT
OR
OVE
RLOAD
Mo
tor Co
nt
ro
ller
ERD
Mi
n
Ma
x
Se
ns
itivity
230V
AC
ON
PO
WE
R
OF
F
MAX
P
S-24
POWER
SUP
PL
Y
FU
SE
7 AM
P
IN
Ma
de
in
U
SA
Select Input V
oltage:
115V
AC or 230
VA
C
warranty
VOIDED
if label is
REMOVE
D
disconnec
t
power before
ser
vicing unit
WARNIN
G
W
AR
NIN
G
HIG
H
H
IG
H
VO
LT
AGE
VO
LT
AG
E
!
MAX PS-24 Power Supply
POWER
IN
POW
ER/
SOL
AR
IN
BAT
TER
Y
IN
www
.m
ax
.us
.com
Made
in
US
A
BA
TTE
RY
PA
CK
TO M
OT
OR
CONTROLLE
R
E
1/2
Batt
ery
Vo
ltage
Rep
lac
e
Ba
tte
ry
ON
/OF
F
Ba
tte
ry
TE
ST
Ba
tte
ry
Ba
tte
ry
IN
Err
or
F
MAX
BC
-7
Ba
tte
ry
Mod
ule
IMPOR
TA
NT
c
onnect to
“BA
T
T
ER
Y IN”
befor
e us
e
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
MAX BC-7
Batter
y Module
Wiring operator
turn on/off operator power
Turn AC Power Switch ON
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
To turn OFF ALL POWER:
1.
Turn OFF
AC POWER Switch
on MAX PS-24 Power Supply. Battery power
remains ON
.
2.
WAIT
for 15 seconds.
3. Press and HOLD
(approx. 5 seconds) the
YELLOW
ON/OFF BATTERY
button
until MAX BC-7 LEDs turn
ON
, then release button. LEDs will turn
OFF
.
Battery power
automatically
turns
ON
.
Operator should have
Input AC power wired
to PS-24,
24V
&
RS-485
wired between Matrix 1 and MC-100 and “Optional”
Key
Switch
wired to MC-100.
TURN POWER ON
. Certain LEDs should normally turn ON accordingly:
AC IN LED:
Normal
- Turns ON.
Error
- Not ON. Check AC power.
7 Amp Fuse blown. Replace fuse.
Input AC selector switch
MUST
be set to
CORRECT
input AC power.
POWER LED:
Normal
- Turns ON.
Error
- Not ON. Check
POWER IN
plug on back of MC-100.
Matrix On-Line LED:
Normal
- Turns ON.
Error
- Not ON. Check
RS-485
wiring to Matrix 1.
Limit SW On-Line LED:
Normal
- Turns ON.
Error
- Not ON. Check
LIMIT SWITCH
plug.
BATTERY VOLTAGE LEDs:
Normal
- 3 LEDs turn ON - Fully charged batteries.
Batteries need charging
- LEDs will turn on in sequence until batteries are
fully charged. Batteries are
NOT
necessary when AC power is available.
BATTERY IN ERROR LED:
Normal
- Not ON.
Error
- Turns ON. Battery not plugged in to
BATTERY IN
port.
POWER LED:
Normal
- Turns ON.
Error
- Not ON. Check
24V
wiring from MC-100
Primary
/Single.
Motor On-Line PRIMARY LED:
Normal
- Turns ON.
Error
- Not ON. Check
RS-485
wiring to
Primary
/Single MC-100.
Limit SW On-Line PRIMARY LED:
Normal
- Turns ON.
PRIMARY GATE OPEN RIGHT OPEN LEFT LED:
Normal
- Turns ON either LED according to switch setting.
Error
- Not ON. Check
LIMIT SWITCH
plug on back of MC-100.
BATTERY IN USE LED:
Normal
- Not ON.
Error
- Flashes on and off. Battery not plugged in to
BATTERY IN
port on
BC-7 Battery Module.
MAX PS-24 Power Supply
MAX MC-100 Motor Controller
Matrix 1
MAX BC-7 Battery Module
1
2
3
4
DO NOT CYCLE GATE OPERATOR
AT THIS TIME