29
matrix 1
ON/OFF
Switch
7-Day Timer
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
OPEN
OBD PORT
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
UL
ENTRAP
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
PEN
STOP
ER
EXIT
CENTER
REVERSE SENSITIV
OTOR OVERLOAD
WITCH /
PING
MAX
IN
OFF
ST
DR
gate disable
GND
GA
TE DISABLE
ON
OFF
GATE DISABLE
prevents breaking into
a keypad box and
trying to trigger the
wires to get the gate
to open.
An ON/OFF switch or timer can be connected to the
GATE DISABLE
input that
will
DISABLE
all opening devices such as remotes, keypad, exit loop etc.
Except
for
FIRE DEPT
and/or
MAX OPEN
inputs.
This is useful when the gated area needs to be secured from
ALL
but emergen-
cy vehicle entry. Some examples are: Residential home vacation period or
during closed hours of a business
ON/OFF Switch Connected:
When turned
ON
, disables
ALL
normal opening
devices (remotes, keypad, exit loop etc.) until switch is turned
OFF
.
Timer Connected:
Can be set for a scheduled timed gate disable period to
disable
ALL
normal opening devices (remotes, keypad, exit loop etc.) until
scheduled time period has expired.
IMPORTANT:
It is
NOT
recommended activating this device while persons are
present inside the property.
EXIT LOOP
Metal
Pl
ate
IMPORTANT:
Limit switches
MUST
be
learned
BEFORE
Partial
Open can be recorded.
To
RECORD
PARTIAL OPEN:
1.
With gate in
CLOSED position
, press and release
PARTIAL OPEN
button to START recording. Blue LED starts flashing.
2.
Press 3-button station
OPEN
button to start gate’s open cycle.
3.
Press 3-button station
STOP
button when gate is in desired partial open position (Beyond center loop).
4.
Press
PARTIAL OPEN
button AGAIN to STOP recording. Blue LED stops flashing,
open position has been recorded. LED remains
ON
.
To
ERASE
PARTIAL OPEN recording
:
Press and
HOLD
PARTIAL OPEN
button for 5 sec. LED turns
OFF
.
A gate can set to partially open by recording the
PARTIAL OPEN
gate cycle. LED will stay lit
when
PARTIAL OPEN
is ON.
partial open
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
CLOSE TIMER
MAX
MIN
OFF
SAFETY
MAX
GATE SPEED
POSITION
RECORDER
REVERSE
12VDC
OPEN
STOP
CLOSE
POSITION
RECORDER
PARTIAL
OPEN
MOTOR MOTION
CAUTION:
Gates partial
OPEN
position
MUST
be outside the
Center Loop when in-ground
loops have been installed.
CENTER LOOP
GATE DISABLE
prevents trying
to trigger the exit loop to
get the gate to open.
NOTE:
The
FIRE DEPT
and/or
MAX
OPEN
connected devices will always
FULLY
open gates even when the
partial open is recorded.