16
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo Cell
GND
Jog R
T
Jog L
T
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
Wiring operator
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
I
J
K
L
M
A
B
C
D
E
F
G
I
K
H
J
L
M
BATTERY Plug:
MUST
be plugged into
BATTERY IN
port
Before
use.
POWER/SOLAR IN Port:
MAX PS-24 Power Supply connection.
Battery Voltage LEDs:
Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
ON/OFF Battery Button:
IMPORTANT:
Battery power
automatically
turns
ON
when MAX PS-24 Power
Supply
AC POWER
Switch
is turned
ON
.
To turn OFF
ALL POWER
to operator:
1.
Turn OFF
AC POWER Switch
on MAX PS-24 Power Supply.
Battery
power
remains ON
.
2.
WAIT
for 15 seconds.
3. Press and HOLD
(approx. 5 seconds) the
YELLOW
ON/OFF BATTERY
button until MAX BC-7 LEDs turn
ON
, then release button.
LEDs will turn
OFF
.
Replace Battery LED:
Replace battery when lit.
TEST Battery Button:
Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
Battery IN Error LED:
Lights when there is a battery connection problem.
Make sure battery plugs are correctly installed and there is no damaged or
loose wires.
MOTOR OVERLOAD LED:
Excessive current being drawn by motor when lit.
ERD LED:
ERD sensor has been activated when lit.
ERD Sensitivity Knob:
Changes sensitivity of ERD sensor.
ERD Sensitivity LED:
MAX sensitivity reached when lit.
Jog LEFT/RIGHT Buttons:
Push and
HOLD
buttons accordingly to move the gate (release the button to
stop gate).
WARNING:
Avoid moving arm while using Jog buttons.
INPUTS:
Jog
LT/RT:
Connects to External Open/Close Key Switch. Connect a
single key switch to control dual gate operators, See page 32.
GND:
Low Voltage Common connection.
Edge
1:
Connects to a Sensing Edge. Multiple sensing edges can be
connected.
Edge
2:
Connects to a second Sensing Edge. Multiple sensing edges can
be
connected.
PHOTOCELL:
Connects to a UL 325 Standard
OPENING Cycle
photocell
ONLY
. Multiple
OPENING Cycle
photocells can be connected.
Matrix On Line LED:
Gate operator is successfully communicating with
Matrix 1 when lit.
Limit SW On Line LED:
Limit Switch Box is successfully communicating
with MC-100 Motor Controller when lit.
Edge 1 LED:
Reversing Edge 1 input has been activated when lit.
Edge 2 LED:
Reversing Edge 2 input has been activated when lit.
UL Entrap LED:
Edge1/Edge2/Photocell input has been activated when lit.
Photocell LED:
Photocell input has been activated when lit.
Power LED:
Low voltage power is connected when lit.
OPENING
Cycle
Photocells
ONLY.
24V ONLY
Photocell
Power.
Photocell (N.O.)
Edge 1
(N.O.)
Edge 2
(N.O.)
GND
GND
GND
24V
24V
RS-485
GND
Sensing Edges
To Matrix 1
Gate Operator System Overview continued
MAX MC-100 Motor Controller
DUAL GATE OPERATORS NOTE:
Connect
EACH
photocell/reverse
edge to the
corresponding gate operator
. See page 8.
POWE
R
IN
PO
WER/SOLAR
IN
BA
TTER
Y
IN
www
.max.us.co
m
Made
in USA
BA
TTER
Y
PACK
TO MOTOR
CONTROLLE
R
E
1/2
Batte
ry V
oltage
Replace
Batte
ry
ON/OF
F
Batter
y
TEST
Batter
y
Batte
ry IN
Erro
r
F
MAX BC-7
Batte
ry Modul
e
IMPORT
ANT
connect to
“BA
TT
ER
Y IN”
before use
E
1/2
Ba
tter
y V
olt
ag
e
Re
place
Ba
tte
ry
ON
/OFF
Ba
tte
ry
TE
ST
Ba
tter
y
Bat
tery
IN
Error
F
MAX
BC-7
Ba
tter
y Mo
du
le
Ma
de
in
US
A
3
4
5
6
7
1
2
MAX BC-7 Battery Module
External Open/Close
Key Switch,
Dual Gate Operators
See page 32.