23
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
12 VDC
OR
24 VDC
Radio Power
12 VDC
OR
24 VDC
Photocell Power
Card Reader
CLOSE
Cycle Photocells
ONLY.
See page 13 & 30.
IS NOT
UL 325 entrapment protection type B1.
OPEN
Cycle
Photocells
ONLY.
Separate
power
for Devices.
Keypad
Photo Cell (N.O.)
Photocell (N.O.)
Edge 1
(N.O.)
Edge 2
(N.O.)
RS-485
250 mA Max.
Stop
GND
GND
GND
Key Lock
Telephone Entry
3-Button
Station
See page 30.
Additional
Reset Button
See page 30.
Gate Disable
Switch or Timer
See page 29.
External
Open/Close
Key Switch,
Dual Gate
Operators
See page 32.
MC-100 Motor Controller
See page 17
Secondary Operator
Connect to MC-100
See pages 20 & 31.
See page 26.
Plug-In
Loop Detectors
See page 27.
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Gate Tamper:
See page 28.
24V Power for Matrix 1
ONLY
.
See page 31.
ID Plug:
See page 28.
ID Plug Error LED. See page 30
4-Wir
e
Radio
3-Wire
Radio
ON
OF
F
ON
1
2
3
4
5
6
7
8
5 =
Optimum Sens.
=
Inc
rease Sens.
=
Decrease Sens.
DE
FLECTO
ME
TER
POWER
ON =
Nor
mal Powe
r
OFF= N
o Pow
er
LED
INDICA
TO
RS
DETECT
ON =
Detect
OFF=
No
Detect
2 Hz
Flash
=Delay
Timing
SW1
SW
2 Fre
quen
cy
ON
ON
=
Low
ON
OFF
= Medium
-Low
OFF
ON
= M
edi
um-H
igh
OFF
OFF
= Hi
gh
SW4
SW
5 O
utput
B
ON
ON
= Pu
lse
on Entr
y
ON OFF
= B sam
e as
A
OFF
ON
= Pu
lse
on Ex
it
OFF
OFF
= Loop
Fau
lt
SW
3
ON
= Fail
Sec
ure
OFF
=
Fail
Saf
e
SW
6
ON
= 2
Sec
ond Delay
OFF
=
No
Delay
SW
7
ON
= N
orma
l Presence
OFF
=
Inf
ini
te Pres
enc
e
SW
8
ON
= Sensitivit
y Boo
st
OFF
=
No Sensiti
vity Boost
Loop
Faul
t
1 Fl
ash
= Ope
n Loop
2 Flas
hes=
Sh
orted Lo
op
3 Flash
es=25
%
chan
ge
of
Indu
ctanc
e
Bot
h LE
D’s Fl
ashi
ng=
Cu
rren
t Loop
Faul
t
PWR
LED
Flashin
g=
Previo
us L
oop
Fault
ED
I
Tel: 480.
968.640
7
DE
FLECTO
ME
TER
SEN
S
RESE
T
POW
ER
DE
TEC
T
ED
I
SEN
S
LMA180
0
OPTIONS
1
2
3
4
5
6
7
8
O
N
UL LED Indicators
ONLY
.
See page 28.
Strobe Light
See page 30
Emergency/Security Devices
Security Device
Security Device
Normal Opening Devices
Normal
Opening
Device
Normal
Opening
Device
GA
TE OPE
N
GA
TE CLOS
ED
UL 325
Entrapment
Protection
Type B1
See
page 13.
Maglock Connection:
See page 27.
Sensing Edges: See page 13.
Connect to Edge 1 and/or Edge 2.
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo Cell
GND
Jog R
T
Jog L
T
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
matrix 1
PR
ES
S
to RESET
Power
Motion
Sensor
Security
Camera
Gate Status:
See page 30
.
Dry Contact
(N.O.)
Dry Contact (N.O.)
(N.C.)
(N.O.)
(N.O.)
wiring Overview
See page 28.
Sec
ondar
y
Op
erator
NO Matrix
1
In-Ground Loops
See page 27.
Safety Loops Wired in series
Center
Loop
Safety
Loo
p
Safety
Loop
Exit
Loop