14
Run
in-ground
loops conduit
to
GATE
OPERATOR
.
Install in-ground loops to help protect vehicles from a moving gate. See pages 23 & 27 for wiring instructions.
Refer to loop maunufacturer’s
instructions to determine
specific loop dimensions.
It is recommended that a
licenced installer perform
this work.
Center
Loop
Safety
Loop
Safety
Loop
Exit
Loop
4 ft
4 ft min.
4 ft
4 ft
4 ft
4 ft
4 ft
4 ft
1 1/2”
Typical
1/4” Saw Cut
Saw Cut
Backer Rod
Loop Wire
Pavement
Sealant
Illustration not to scale
Side View of
Saw Cut
Loop lead wires are
twisted 6 twists per
foot minimum inside
conduit.
Safety Loops
Are placed on each side of the gate to
prevent the gate from closing on a
vehicle in it’s path. They will stop or
reverse the cycling of the gate while a
vehicle is in or near the gate’s pathway.
Center Loop
Will
ONLY HOLD
the gate in the
Full
Open Position
when a vehicle is on the
center loop. However, it
WILL NOT stop
or reverse
the gate once it starts to
close.
Exit Loop
Automatically opens the gate for exiting
vehicles without having to use a radio
transmitter (remote control). The exit
loop can be placed a minimum of 4 feet
away from the safety loop or far enough
away from the gate so it has opened by
the time the vehicle approaches it.
installation
in-ground loops
Outside Property
Inside Property