background image

Summary of Contents for Pantheon

Page 1: ......

Page 2: ...ruption Pantheon is manufactured to exceed UL325 and CE re quirements Pantheon is designed to suit a 9 1 2 drum mini series The Pantheon mini operator is comprised of two parts a logic controller and a drive unit with floor level manual release lever Drive Unit Features Low voltage DC motors Internal planetary gearing mechanism Soft start soft stop Electronic limits Floor level cable operated manu...

Page 3: ... Limits Unique electronic and mechanical design that enables the required opening and closing positions to be set electronically and retained despite any main power fluctuation or interruption Simple three step process no cams levers screws or micro switches Floor Level Cable Operated Manual Release No power no lights No need for a ladder Simple activation of the lever will enable the door to be o...

Page 4: ...e UP DOWN STOP Buttons and Status Indicator Panel Flush mounted buttons Illuminated LED status indicator panel AUTO Close Selectable if required for auto closing of the door after a prescribed period of time In the event that the closing sequence is interrupted and the door returns to the fully open condition the timer will reset automatically and commence the countdown process Momentary or Consta...

Page 5: ...ely event that the overload or sensitivity software has failed to detect a fault Alarm Plug in terminal connection provides constant 12 V DC signal in the event that an attempted forced entry is detected by the operator Simple interface with external alarm device consult alarm manu facturers for details Key Switch Connection Plug in terminal connection for simple wiring of external key switch devi...

Page 6: ...ly in conjunction with the electronic sensi tivity will cause the operator to stop and reverse its downward closing motion if it encounters an obstruction In such an event the operator will detect the obstruction and reverse the direction of the closing door returning it safely to the fully open position This feature does not replace the requirement for an external entrapment protection device but...

Page 7: ...ill deem that where an ex ternal entrapment device is connected as required it shall be monitored by the software The logic controller will not permit the operator to function to close if the entrapment device is faulty unless the DOWN button is activated by constant contact Toroidal Transformer Superior performance and consistent power supply More efficient than traditional iron block style Manuf...

Page 8: ...will come to rest gently and smoothly helping to prolong the motor life The logic control has individually controlled opening and closing force adjustments to compensate for small opera tional imbalances which ensures that the door is operating at its optimal level Connections of external devices are simple and easy to complete with removable plug sockets which allow the wiring to be done away fro...

Page 9: ...INSTALLATION INSTRUCTIONS COMMERCIAL MODEL www janusintl com ...

Page 10: ...spring tension and side clearances the commercial rolling door must operate in the manual condition without binding or sticking in the guides x INSTALL the logic controller in a suitable location at a minimum of five 5 feet from the ground and maximum of three 3 feet from the edge of the opening and in clear sight of the surrounding areas x OBSERVE local and national safety codes including but not...

Page 11: ... technician x LOCAL AND STATE safety regulations may require the connection of an external entrapment protection device when certain optional operational features of the operator are selected These include the use of timer devices auto close feature momentary contact to close and the use of remote control transmitters x PRIOR TO OPERATING the door ensure that you are familiar with the full operati...

Page 12: ...into the threaded recess Withdraw spring loaded pin and twist to engage manual release Fit split nut and tighten Carefully coil cables together and secure with a cable tie or similar to prevent uncoiling or damage during the installation of the rolling door STEP 1 Connecting the manual release cable to the drive unit ...

Page 13: ...anchor bracket Carefully insert the two tubes of the assembled bracket into the corresponding sections of the drive unit Ensure that maximum penetration of the tubes into the drive unit is achieved STEP 2 Fitting the dual anchor bracket to the drive unit 1 2 3 4 5 ...

Page 14: ...lling door on the appropriate end of the door the steel drum wheel is recessed during the manufacture of the door to accommodate the fitment of the drive unit Ensure that the spigots on the back of the drive unit are e n g a g e d w i t h t h e corresponding holes in the steel drum wheel STEP 3 Preparing for the installation of the rolling door PARTS AS SHOWN E X P O S E D F O R P U R P O S E S O ...

Page 15: ...guide Spring tension and curtain clearances should be maintained as per normal practice A U bolt nuts are provided with a cast iron saddle to secure the axle of the door to the support bracket STEP 4 Proceeding with the installation of the rolling door NOTE OF CAUTION Take care to ensure that the cables from the drive unit are not damaged or permitted to bind on any part of the structure or the do...

Page 16: ...ontroller shall be installed on the same side of the opening as the drive unit The logic controller shall be installed at a minimum of five 5 feet from the ground and a maximum of three 3 feet from the edge of the opening and with a clear view of the surrounding area The front cover is secured with four captive screws If required carefully unplug the main control panel loom plug from the ter minal...

Page 17: ... fitment Fit the cable gland strain relief bushing to the four wire drive unit cable and fit the cable through the hole provided at the bottom of the enclosure remove the plug in section of the terminal and connect the wires in accordance with the detail provided As per factory issue the logic controller is designed to operate with momentary contact to OPEN and constant contact to CLOSE STEP 5 fit...

Page 18: ...o match the drive unit installation move the DIRECTION jumper to the required position LH OPERATION RH OPERATION NOTE OF CAUTION ALWAYS SWITCH MAINS POWER OFF WHEN HANDING THE OPERATOR STEP 6 Handing the operator to suit the installation LH or RH side drive This handing feature does not apply to Pantheon mini operators All Pantheon mini operators will have the direction jumper removed and fitted t...

Page 19: ...the head stops 3 When the OPEN position is achieved press the LEARN button once two BEEP sounds will confirm the setting The logic controller is now ready to learn the CLOSED position 4 Press and hold the DOWN button until the door moves to the required CLOSED position Small adjustments may be made by momentary pressing of the UP or DOWN button to move the door to the required position 5 When the ...

Page 20: ...t S and check that the door will operate without reversing or stalling If required move the jumper through the ranges M L XL until satisfactory operation is achieved Final adjustment of the sensitivity setting is performed by following the instructions as set out under the heading SENSITVITY ADJUSTMENT step 9 NOTE OF WARNING IT IS ESSENTIAL THAT THIS FEATURE IS NOT RECOGNISED AS AN EXTERNAL ENTRAP...

Page 21: ...ctronic sensitivity setting has been confirmed refer to instructions under the heading Setting the sensitivity adjustment previous page step 8 Fine tuning is performed by careful rotation of the corresponding open or close setting as required To increase the sensitivity of the operator rotate the required open or close setting ANTICLOCKWISE To decrease the sensitivity of the operator rotate the re...

Page 22: ... rotate to engage the mating hexagonal sections NB main parts removed for photographic clarity Secure the shaft in position ensuring that the screw does not prevent free rotation Fit the cast chain wheel and nylon guide retain with split pin cut chain to length and fit to chain wheel An exploded assembly drawing is contained in the accessory carton for reference STEP 10 Fitting the manual chain ho...

Page 23: ...rd the right to actuate full auto operation Re engage the manual release pin at the drive unit ensure the drive unit is fully engaged by gently moving the curtain of the rolling door in either direction up or down until the pin is locked into position Check that the lever is able to withdraw the manual release pin and re engage it as required Adjust the lever tension screw if required to hold the ...

Page 24: ... accessories Contact Information Janus International 134 Janus International Blvd Temple GA 30179 770 562 2850 770 562 1991 fax www janusintl com STEP 12 Commissioning and handover of the door and operator Check List Check activation of manual release lever Check auto reverse function Check auto close if selected Check timer device if connected Check photo electric sensor function if connected Che...

Reviews: