matrix 1 led continued
Matrix 1 LED
Problem Condition
Solution(s) for
Problem Condition
Normal
LED
“PHOTOCELL” LED is ON
“PHOTOCELL” LED is FLASHING
“MOTOR OVERLOAD” LED is ON
“NO LIMIT SW /
CLAMP SLIPPING
” LED is ON
“EXIT” LOOP LED is FLASHING or
contstantly ON
“SAFETY” LOOP LED is FLASHING or
contstantly ON
“GATE DISABLE” LED is ON
“MAG LOCK” LED is FLASHING
“GATE TAMPER” LED is FLASHING
“12VDC” LED is OFF. “24VDC” LED is OFF
•
Jumper between PHOTOCELL and GND is missing or broken (jumper is required if a sensor is not
present).
•
Sensor on PHOTOCELL input (photocell or edge) may have detected an obstruction while opening or
closing gate.
•
Photocell on PHOTOCELL input is misaligned with reflector.
•
Sensor on PHOTOCELL input (photocell or edge) may not be wired properly, (see ).
•
Sensor is NOT a N.C. monitored sensor that is UL325 2016 compliant.
•
Sensor on PHOTOCELL is damaged or malfunctioning.
•
Sensor might need to be re-learned.
•
Check if gate is binding against catch post or bracket in opened or closed position.
•
Check if gate moves manually with low resistance throughout its full range of motion.
•
Check if chain is installed inline with idle wheels in both OPEN and CLOSED positions.
•
Gate may be too heavy for operator (check manual for maximum gate capacity).
•
Check if OPEN and CLOSE magnets are still connected on chain.
•
Loop fault condition: Check if EXIT loop wires are connected into to loop input connector properly.
•
Check if loop detector is inserted properly in Matrix 1 slot.
•
Set unique loop detector frequency for each loop detector used.
•
Loop Detector might be defective. Replace defective loop detector.
NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).
•
Loop fault condition: check if SAFETY loop wires are connected into to loop input connector properly.
•
Check if SAFETY loops are wired in series.
•
Check if loop detector is inserted properly in Matrix 1 slot.
•
Set unique loop detector frequency for each loop detector used.
•
Loop Detector might be defective. Replace defective loop detector.
NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).
•
Check if “Gate Shut-off” switch is ON, Turn it OFF. If it is OFF, cycle the switch (ON then OFF).
•
Check if the chain is dropped. If so, gate is disabled for safety. Re-install chain and cycle the "Gate
Shut-off" switch (ON then OFF) to enable operator.
•
Check if an external device is triggering GATE DISABLE input on Matrix 1. Disconnect devices
individually to determine possible false triggering of GATE DISABLE.
•
Maglock power is lost. Check if maglock power transformer is wired properly to Matrix 1 or needs to be
replaced.
•
Switch is set to delay but no maglock is connected. Set switch to OFF
•
Gate was manually moved off of its CLOSED position causing Tamper Relay to trigger for few seconds.
•
Check for a short in wiring to connected device. DO NOT power external keypads or telephone entry to
this port (only use for radio receiver / photocell).
OFF
12
OFF
12
OFF
18
OFF
19
OFF
1
OFF
3
OFF
22
OFF
10
OFF
11
ON
4 or 5
7
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
15. ID PLUG ERROR
14. EDGE 2
13. EDGE 1
12. PHOTOCELL
16. UL ENTRAPMENT
17. REVERSE SENSITIVITY
21. POWER
22. GATE DISABLE
8. SECONDARY MOTOR ON-LINE
9. PRIMARY MOTOR ON-LINE
6. SECONDARY LIMIT SWITCH ON-LINE
1. EXIT LOOP
2. CENTER LOOP
3. SAFETY LOOP
7. PRIMARY LIMIT SWITCH ON-LINE
20. BATTERY IN USE
10. MAGLOCK
11. GATE TAMPER
4. 12 VDC
5. 24 VDC
18. MOTOR OVERLOAD
19. NO LIMIT SWITCH
CLAMP SLIPPING
ID plug
MUST
be plugged in.
MAX 1500
MAX 2200
MAX F1
8
MAX
1500
MAX 2200
MAX F1
8
18
UL 325 2016 Standard-MAX Quick Install Rev 8