wiring opening device options
12
Maglock
Power
Pos
Neg
Pos
Neg
Maglock
+
+
-
-
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
12 VDC
OR
24 VDC
Radio Power
250 mA Max.
4-W
ire
Radio
3-Wire
Radio
Card Reader
Separate
power
for Devices if required.
Keypad
Key Switch
Emergency OPEN
(Overrides gate
disable switch)
Emergency Open Device
Dry Contact
(N.O.)
(N.O.)
NOTE:
See manual for more info.
Stop
Com
External Alarm
Reset Button
Security Device
PRESS
to RESE
T
Telephone
Entry
Dry Contact (N.O.)
Normal Opening Devices
Normal Opening Devices
MAGLOCK DELAY:
You
MUST
select a time delay when using
a maglock. Maglock power disengages 1.5
sec
or
2 sec
before
gate starts opening.
MAGLOCK LED (Monitors Maglock):
ON
- Locked
OFF
- Unlocked
Flashing
- Problem with Maglock Power.
MAG
LOCK
MAGLOCK
DELAY
OFF
2Sec
1.5Sec
Dual Gate Operators using Maglock:
Primary gate opens
FIRST
.
Install maglock accordingly to account for this.
Maglock
MUST
be connected as shown
when used.
maglock option
10
UL 325 2016 Standard-MAX Quick Install Rev 8