24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
E
T
T
ER
ER
R
R
R
R
R
R
R
Press Together
Gate Tamper
LEDs
gate tamper feature
Many different safety devices can be wired to the
GATE TAMPER
. After device is wired to relay, it
MUST
be
ARMED
to function.
Security
Camera
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
ID
PLUG
PARTIAL
OPEN
CLOSE TIMER
MAX
PHOTOCELL
OFF
SAFETY
CENTER
OFF
ON
EXIT
GATE
TA
Tamper NO
Wiring Gate Tamper
GATE
TAMPER
Tamper NO
COM
GND
Tamper IN
The
GATE TAMPER
can be used for various functions
such as turning a warning light, siren or camera on
when the gate is tampered with (Vandalized Gate).
The gate operator defines a “Vandalized Gate” as
UNAUTHORIZED
movement of the gate. This can
occur if the chain is dropped and gate is manually
moved from the
closed position
or the gate is forced
open from the
closed position without authorization.
TAMPER NO/Com Relay:
Connect a warning light, siren, camera or
an existing alarm system to relay.
TAMPER IN/GND Input:
Connect a sensor device to input. When
Tamper In/GND gets triggered, device that is wired to Tamper relay
(NO/Com) will activate.
Arm Gate Tamper (Turn ON)
Siren
Warning
Light
Motion
Sensor
Power
Power
Existing
Building
Alarm
System
The
GATE TAMPER
is factory set to
OFF
(Unarmed). It
MUST
be turned
ON
(Armed) or safety device connected to the
GATE TAMPER
relay will
NOT
activate.
•
Press and
HOLD
the
STOP
button while simultaneously pressing
the
POSITION RECORDER
button. Hold
BOTH
buttons down until
Gate Tamper LEDs light up then turn OFF and a beep is heard.
Gate Tamper
is now
ARMED (ON)
.
NOTE:
DO NOT
press the
POSITION RECORDER
button before
the
STOP
button or Gate Tamper will
NOT
Arm.
•
To
UNARM (Turn OFF) Gate Tamper
repeat above step.
When
GATE TAMPER
is triggered, the
OPERATOR ALARM
and
GATE TAMPER
relay will activate. The operator will shut
down all operating functions.
The alarm reset button
MUST
be pressed to
turn
OFF
the alarm and reset the operator.
If
GATE TAMPER
is armed and relay is connected to
an existing building alarm system, then they will get a
triggering of their alarm system and should be
notified of the situation.
Alarm Reset Button
12