MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
Gate
Tamper
Relay
The
GATE TAMPER
is factory set to
OFF
(Unarmed). See previous page for more information about
ARMING GATE TAMPER
.
If an existing alarm system (Building alarm system) is connected to the
GATE TAMPER
relay (see previous page), notify proper
authorities
BEFORE dropping the chain.
IMPROPER Dropping of Chain (Vandalize):
Gate Shut-Off switch is
NOT
turned
ON
.
When the chain is improperly dropped (Vandalized), the
OPERATOR ALARM
and
GATE TAMPER
relay will activate. The operator will shut
down all operating functions.
The alarm reset button
MUST
be pressed to turn
OFF
the alarm and reset the operator. If
GATE TAMPER
relay is connected to an existing
building alarm system, then they will get a triggering of their alarm system and should be notified of the situation.
PROPER Dropping of Chain while GATE TAMPER is ARMED:
1.
Turn Gate Shut-Off switch
ON
to disable operator alarm.
2.
Drop the Chain.
3.
GATE TAMPER
relay
WILL
be activated.
4.
Service operator.
5.
Reconnect the chain to gate.
6.
Turn Gate Shut-Off switch
OFF
.
7.
Rearm an alarm system that may be connected to the
GATE TAMPER
relay.
ON
OFF
Gate
Shut-Off
ON
OFF
Gate
Shut-Off
Dropping the Chain - GATE TAMPER is ARMED (ON)
Gate Shut-Off Switch
Alarm Reset Button
13