DS33Z41 Quad IMUX Ethernet Mapper
134 of 167
Register Name:
SU.RxFrmOkCtr
Register Description:
MAC Frames Received OK Counter
Register Address:
0204h (indirect)
0204h:
Bit
# 31 30 29 28 27 26 25 24
Name
RXFRMOK31 RXFRMOK30
RXFRMOK29
RXFRMOK28
RXFRMOK27
RXFRMOK26
RXFRMOK25
RXFRMOK24
Default
0 0 0 0 0 0 0 0
0205h:
Bit
# 23 22 21 20 19 18 17 16
Name
RXFRMOK23
RXFRMOK22
RXFRMOK21 RXFRMOK20
RXFRMOK19
RXFRMOK18
RXFRMOK17
RXFRMOK16
Default
0 0 0 0 0 0 0 0
0206h:
Bit
# 15 14 13 12 11 10 09 08
Name
RXFRMOK15
RXFRMOK14
RXFRMOK13
RXFRMOK12
RXFRMOK11
RXFRMOK10
RXFRMOK9
RXFRMOK8
Default
0 0 0 0 0 0 0 0
0207h:
Bit
# 07 06 05 04 03 02 01 00
Name
RXFRMOK7
RXFRMOK6
RXFRMOK5
RXFRMOK4
RXFRMOK3
RXFRMOK2
RXFRMOK1
RXFRMOK0
Default
0 0 0 0 0 0 0 0
Bits 31 to 0: Frames Received OK Counter (RXFRMOK31 to RXFRMOK0).
32-bit value indicating the number
of frames received and determined to be valid. Each time a valid frame is received, this counter is incremented by
1. This counter resets only upon device reset, does not saturate, and rolls over to zero upon reaching the
maximum value. The user should ensure that the measurement period is less than the minimum length of time
required for the counter to increment 2^32-1 times at the maximum frame rate. The user should store the value
from the beginning of the measurement period for later calculations, and take into account the possibility of a