www.maxcess.com
FIFE-500 MAX Narrow Web Guide
MI 2700XXXXX 18
CHAPTER 4
AUTOMATIC SET GAIN
49 / 77
4.8 AUTOSETUP
The FIFE-500 MAX Web Guiding System gain and
polarity can be set manually as described in other areas of this manual.
Using this menu however, the system gain and polarity can be determined
automatically.
Navigation:
MANUAL
SELECT SENSOR MODE
SETUP
AUTOSETUP
Note: The automatic setup procedure should be done with the web at a
standstill.
Auto setup is performed using the sensor mode that has been selected from
the Operator Level screen. Before auto setup can begin, the web must be
within the selected sensor field of view. The bar graph indicator shows the
acceptable limits for the sensor signal and the Autosetup button will remain
disabled until the proper conditions are present.
Use the jog buttons to position the web edge near the center
of the sensor proportional band as shown below.