www.maxcess.com
FIFE-500 MAX Narrow Web Guide
MI 2700XXXXX 18
CHAPTER 3
SECURITY STRATEGY
21 / 77
3.6.2 Access Modes
The SETUP button on the Operator Level screen and each menu in the FIFE-500 MAX Web
Guiding System has programmable access modes for each of the three possible
authorization levels. The button appearance of each menu item indicates which access mode
is active for the current login authorization level. The possible button appearances are
shown below using the GAIN button as an example.
NO ACCESS The “Lock” icon superimposed on a button indicates
that access is not allowed from the current login authorization
level. Pressing the button will prompt for numeric pass code entry
and will only allow access if the entered code raises the login
authorization level high enough to permit access.
READ ONLY ACCESS The “Magnifier” icon superimposed on a
button indicates that the menu has read-only access from the
current login authorization level. The user is allowed to view the
settings but not change them.
FULL ACCESS The button will appear with no access modifier
when there are no restrictions for the menu. This is also the button