CHAPTER 4
GAIN
45 / 77
When the gain menu is accessed from MANAUL mode, the
AUTOSETUP button will be shown in one of the following two
states, depending on the sensor signal level of the active sensor
mode:
AUTOSETUP is available: The
system is in Manual mode
and the active sensor signal is
within the allowable range.
AUTOSETUP is NOT available:
The system is in Manual mode
but the sensor signal is not
within the allowable range.
If the AUTOSETUP button is not available, use the
larger arrow buttons to jog the guide in either direction, until the
sensor signal is within the allowable range and the AUTOSETUP
button is available.
Press AUTOSETUP to initiate the auto setup gain
and polarity. The guide will move a short distance and the system
gain value will be automatically set.
Press ACCEPT to save changes and return to the previous
screen.
Press CANCEL to exit without saving changes and return to
the previous screen. If the gain has been changed, it will be
restored to its previous value.
WARNING – Death or injury can result from unexpected movement.
Auto-setup operation causes guide movement. Take appropriate
precautions to ensure no one is in the vicinity of the guide path of
travel.