www.maxcess.com
FIFE-500 MAX Narrow Web Guide
MI 2700XXXXX 18
CHAPTER 4
ASC SETTINGS
42 / 77
4.5.3 ASC SETTINGS
This menu controls all
programmable aspects of ASC operation for each
sensor mode. The first three tabs have identical sets
of controls for each sensor mode. The last tab
contains polarity controls to set the polarity used for
each sensor signal during ASC processing.
Navigation:
MANUAL / SERVO-CENTER / AUTOMATIC
SETUP
ASC
ASC SETTINGS
Touch the tab controls at the top as needed to switch to the
desired page before making changes.
ASC State The ASC State button enables or disabled the availability
of ASC use for the selected sensor mode. The LED displayed on the
button indicates the present state. Press the button to toggle the
ASC availability for this sensor mode on or off.
Source Selects the sensor that is monitored for ASC thresholds.
Typically this is the same sensor used for guiding but in some
applications it could be desirable to monitor a different input.
Source input choices include the sensor signal S1, S2, S1+S2, or
S1S2.
Mode The mode setting controls how the source signal threshold
is processed. These modes are used to configure ASC operation for
specific application requirements. There are 6 modes available: