![Matsusada R4G Series Instruction Manual Download Page 58](http://html1.mh-extra.com/html/matsusada/r4g-series/r4g-series_instruction-manual_1741916058.webp)
8 Troubleshooting
50
R4G/R4GE series
8
Troubleshooting
If you think a failure has occurred, first turn off the unit and check the following items.
They are not always a failure in the following cases, check the unit once again before requesting our services.
Problem
Items to check
No output
or the output does not meet
the preset value.
☐
Is the input voltage within the specifications? Is the wiring correct?
☐
Is the CV and/or CC setting minimized?
☐
Is the [OUTPUT ON/OFF] switch set to ON?
☐
Is the [Romote/Local] selector switch set correctly?
☐
Restore the default settings, set the [Remote Sensing] and [Single Control]
switches to OFF to output again.
☐
Is the common grounded in your equipment? (See 7-3.)
Fuse blows
or breaker trips
☐
Have you replaced the original screws of the housing with different ones?
(The replaced screws may have cut into the internal circuits.)
☐
Is the breaker's base capacity sufficient?
Output voltage fluctuates
or gets out of control.
☐
Is it set to CC mode?
☐
Is the input voltage within the specifications?
☐
Are there any noise sources near the unit?
Ripple voltage is large or
oscillating.
☐
Is the input voltage out of the specifications?
☐
Is a special load connected?
☐
Are there any sources for strong magnetic fields or electric fields near the
unit?
*
If any of the above items do not apply to you, or if you have checked but cannot recover, please