7 Analog Control
42
R4G/R4GE series
7-3
Remote Programming
Fluctuations in values of external voltage and external resistance will directly affect the
output, so use a highly stable one.
+
+
-
+
S (common)
+
-
+
S (common)
V
Vmoni
V
Imoni
Output control
Output monitor
* Use the control and monitor voltage as floating, not to ground.
The common, +S, will be at the same potential as the + output
terminal. If the common is grounded in your system, it may result in
the
unit
being
uncontrollable
and/or
system
failure.
Moreover, note that it may be connected to other equipment's ground
via the sequencer when using a multi-channel or non-isolated
sequencer