7 Operating with Digital Control
61
HARS series
7-6 Original Command program by Matsusada Precision
7-6-1 Summary of Syntax
Example: To set the output voltage set in unit 1 to the maximum rating, write as follows.
#1
CH0 FFFF
○○
(
2)Parameter
(
3)Command
(1)Delimiter
(
4)UNIT
number
(1) Input delimiter. See [5-1-19 Delimiter Setting.]
(2) Some commands require a parameter.
(3) Wrong commands are to be ignored.
(4) Specify the UNIT number.
Do not write more than
20 command characters
, including the delimiter.
If a large number of setting commands are sent in succession, the receive buffer may
overflow and not accept the commands.
In this case, please add a wait between each command.
7-6-2 Multiple command
By using “AL” for UNIT number, the command is sent to all the connected units
(Syntax example) (1) #AL CH0 FFFF
All the units are set to the maximum rated votage.
(2) #AL OUT ON
All the units enable to output.
(remarks) Commands applicable to Multiple command: CH0, CH1, CH2, CH7, VCN, ICN, OVP, OCP,
VSET, ISET, OVPSET, OCPSET, OVLSET,
OCLSET, OUT, REN, GTL