6 Operating by Analog Remote Control
53
HARS series
6-8 Status Output
Item
TB1 connector pin
Output
Common
Status output
(Output by open collector)
Use Breakdown voltage 30V or less,
SINK current 5mA or less.
HV status
19
17
CV status
13
CC status
12
FLT status
11
*The contact between output pin and
common at time of status output
should be shorted
CAUTION
17
External connecton
5mA
or less
Vcc = 24V
R = 4.7kΩ
Vcc
R
Analog remote connector
PIN17 PIN11 or 12 or 13 or 19
Common
13
25
14
1
The internal photocoupler
is turned on with the status
output.
Internal circuit
of unit
22Ω
22Ω
22Ω
22Ω
19
13
12
11