13
5.3 TRoUblESHooTINg - EXCESSIVE PlAy IN HEIgHT ADJUSTMENT lEVER - CoNTINUED
CHAPTER 5: TRoUblESHooTINg
7) Check the connection of the pivot handle cable to the pivot handle fulcrum (Figure E). The cable should be tight. Re-attach or tighten as
needed.
8) Once the pivot handle cable is correctly attached, re-install the pivot handle (Figure F) and test the rotation before installing the shrouds to
make sure that the tension on the pivot handle is correct.
9) Once the pivot handle cable is connected correctly, remove the pivot handle and re-install the pivot handle shroud and the other shrouds.
10) Once all of the shrouds are re-installed, re-install the pivot handle and the tension knob. Also re-install the cranks.
11) Test the Krankcycle for function.