2. SPECIFICATIONS
2.1
PV Input
Input Type
Thermocouple (E, J, K, T, B, R, S), RTD (Pt100),
Current, Voltage
Display Range
Refer Table-1
Accuracy
+ (0.25% of Full Span + 1 degree) for T/C and RTD
input.
+ (0.1% of Full Span + 1 count) for Linear input.
ADC Resolution
16 bits
Display Resolution
0.1 / 1 °C
Sampling Rate
5 Samples/Sec
CJC Error
±2.0 °C Max
Sensor open Detection
All inputs except 0-5V, 0-10V
Sensor Burnout current
0.25uA
RTD excitation current
0.16mA (Approx)
NMRR
> 40 dB
CMRR
> 120 dB
Temp-co
< 100ppm/°C
Input Impedance
> 1MΩ (Voltage Input)
250Ω (Current Input)
Max Voltage
20VDC
Input type
Range
E
-200 to 1000
C*
J
-200 to 1200
º
C*
K
-200 to 1372
º
C*
T
-200 to 400
º
C*
B
450 to 1800
C
R
0 to 1768
º
C
S
0 to 1768
º
C
PT100 (1
º
C)
-200 to 850
º
C*
1-5VDC /0-5VDC /0-10VDC
-1999 to 9999 (Field Scalable)
4-20mA /0-20mA (Ext. 250ohms, 0.1%)
-1999 to 9999 (Field Scalable)
Table-1
*0.1 °C possible for range -1.99.9 to 999.9
2.2
Display & Keys
Process Value
0.8", 7 segment, White LED, 4 digits
Set Value
0.4", 7 segment, Green LED, 4 digits
Manipulated Value
10 segment bar Orange LED
Keys
Enter, A/M, Increase, Decrease
Status LEDs
For Relay, Communication, A/M,Auto tune, SP1, SP2