44
VDO Face 5™ user manual
P3 system layout: schematic overview
Connecting the P3 link
Warning! In outdoor or humid environments, use only Neutrik EtherCON Cat 6 connectors for P3
signal connections, or panels will not be weatherproof to IP65. We recommend use of the cables
supplied by Martin® for the VDO Face 5™ (see “Data cable” on page 51).
To connect the P3 link:
1. Run an Ethernet cable from the P3 System Controller’s P3 signal output to an input on a 1GB Ethernet
Switch.
2. Run an Ethernet cable from the Ethernet Switch to the Data IN connector on the first panel in the chain.
3. Run an Ethernet patch cable from the first panel’s Data THRU connector to the Data IN connector of the
next panel in the chain and continue connecting panels, Data THRU to Data IN in a daisy-chain. A
maximum of 50 panels may be connected in one chain.
4. If necessary, connect additional chains to the P3 System Controller, running Ethernet patch cables from
the Ethernet Switch outputs to the data input of the first panel on each chain. Respect the layout and
guidelines given earlier in this section.
5. Keep all unused panel connectors sealed with their rubber caps at all times.
6. The system is now ready for power to be applied.
7. Set up the panels to display video as described in the P3 System Controller’s user manual.
DVI
Analog
video
Analog
video
Monitor
Mouse
Keyboard
P3 System Controller
P3 signal
1GB Ethernet
switch
Figure 37: Schematic diagram of P3 system connections
DVI
Analog
video
Analog
video
Monitor
Mouse
Keyboard
P3 System Controller
P3 signal
1GB Ethernet
switch
Summary of Contents for VDO Face 5