Installing Splitters
45
Connecting the hybrid link in a Splitter
To connect a hybrid Splitter cable carrying data and 30 VDC power to a
Splitter:
1. Check that the system is isolated from AC mains power and that
power cannot be reapplied during work on the system.
2. See Figure 21. Prepare a suitable length of Martin™ hybrid Splitter
cable for connection to the Splitter:
• strip 60 mm (2.4 ins.) of the outer cable jacket from the end of the
cable,
Figure 21: Hybrid cable connections in Splitter
Hybrid cable
gland
Data connection:
I-type end caps (10 mm)
DC power connection:
U-type end caps for M3
screws
40
60
shield
Martin™ hybrid cable