16
Martin Professional™ Exterior 50 & 100™ system user manual
System layout limits
Warning! You may interconnect PSUs, Splitters and Luminaires as
described in this section, but the total current draw of any group of
interconnected devices must not exceed 16 amps. Each time you
reach the 16 amp limit, you must create a new group of
interconnected devices with their own connection to AC mains
power.
Warning! Respect the following maximum limits when connecting
Luminaires and Splitters to ANY ONE OUTPUT from an Exterior 50 &
100 PSU:
• Maximum FIVE Exterior 100 Luminaires per output, or
• Maximum FIFTEEN Exterior 50 Luminaires per output, or
• Any combination of Exterior 50 and Exterior 100 Luminaires
within these limits where three Exterior 50 Luminaires are
equivalent to one Exterior 100 Luminaire.
Warning! Respect the following maximum limits when connecting
Luminaires and Splitters to ALL THE OUTPUTS from an Exterior 50 &
100 PSU:
• Maximum TEN Exterior 100 Luminaires in total, or
• Maximum THIRTY Exterior 50 Luminaires in total, or
• Any combination of Exterior 50 and Exterior 100 Luminaires
within these limits where three Exterior 50 Luminaires are
equivalent to one Exterior 100 Luminaire.
Warning! Any one run of hybrid cables that connects a PSU to a
Splitter or chain of Splitters must not exceed a maximum total length
of 50 m (164 ft.) from the PSU to the last Splitter in the chain.
Warning! Any one luminaire cable must not exceed a maximum
length of 13 m (42.6 ft.).