46
Martin Professional™ Exterior 50 & 100™ system user manual
• strip the last 10 mm (0.4 ins.) of the data ground/common, the data
+ve and data -ve wires and install ferrules (I-type end caps) on the
exposed conductors, then
• shorten the two 30 VDC wires, strip the last 10 mm (0.4 ins.) from
them and install U-shaped end caps that accept M3 screws onto the
exposed conductors so that each 30 VDC wire is 40 mm (1.6 ins.)
long including the end cap.
3. See ”Installing a cable in a cable gland” on page 23. Pass the hybrid
Splitter cable through one of the hybrid (larger cable diameter) cable
glands on the Splitter as shown in Figure 21.
4. See Figure 22. Connect the wires from the hybrid Splitter cable to
either of the hybrid cable terminals in the Splitter as follows:
• Connect the braided copper and/or foil shield data ground/common
conductor to the terminal marked
GND
.
• Connect the red data +ve (hot) wire to the terminal marked
DMX+
.
• Connect the green data -ve (cold) wire to the terminal marked
DMX-
• Connect the white 30 V +ve (hot) wire to the terminal marked
+U
.
• Connect the black 30 V -ve (cold) wire to the terminal marked
-U
.