Menu
Second-level
menu
Sub-menu
Explanation
DMX Setup
DMX Address
1-491
Fixture DMX address setting
Personality
Pan Inverse
No
Yes
Invert DMX pan control: right
→
left
Tilt Inverse
No
Yes
Invert DMX tilt control: down
→
up
Dimmer Curve
Linear
Optically linear dimming curve
Square Law
Square law dimming curve
Inv SQ Law
Inverse square law dimming curve
S-Curve
S-curve (fixture emulates incandescent
lamp voltage linear RMS dimming curve)
Dimmer Speed
Fast
Snap dimming (fast dimmer speed)
Slow
Fade dimming (slow dimmer speed)
No Data Mode
Blackout
If data connection is lost, fixture will
blackout
Hold
If data connection is lost, fixture holds
latest received data value at all channels
Cooling Mode
Regulated fan
Fan optimized for light intensity
(temperature controlled by regulating
fan speed, light output unaffected)
Full
Fans set to full constant speed
Display
Display Rotation
(
Normal
/Rotate
180)
Display orientation normal/rotated 180°
Display Intensity
('10-
100
)
Set display intensity in % (default = 100)
Temperature
unit(
°
C
/
°
F)
All temperature readouts in C°/ F°
Default
Settings
Factory Default
No
Yes
Return all settings (except calibrations) to
factory defaults
Fixture Test
Test All
Run test sequence of all functions. To test
a specific function, use Up/Down buttons
to scroll through functions and pause.
Press Enter to restart test sequence. Press
Menu button to exit test.
Test Dimmer
Run test sequence of LEDs only. To test a
specific LED group, use Up/Down buttons
Summary of Contents for ERA 300 Profile