Dimming curves
Four dimming modes are available:
LINEAR
The increase in light intensity appears to be linear as DMX value
is increased.
SQUARE
LAW
Light intensity control is finer at low levels and coarser at high
levels.
INV SQ
LAW
(Inverse square law) Light intensity control is coarser at low levels
and finer at high levels.
S-
CURVE
Light intensity control is finer at low levels and high levels and
coarser at medium levels.
To set the fixture’s dimmer curve, select DIMMER CURVE from the PERSONALITY menu and
press ENTER to confirm. Use the UP and DOWN buttons to select the desired mode. Press
ENTER to save your selection.
Dimmer Speed
You can set a fade speed on the dimmer to simulate a tungsten fixture.
To set dimmer fade speed, select DIMMER SPEED from the PERSONALITY menu and press
ENTER. Use the UP and DOWN buttons to select FAST or SLOW. Press ENTER to confirm your
selection.
No Data Mode
This option sets what will happen when DMX data is not present.
To set No Data Mode, select NO DATA MODE from the PERSONALITY menu and press ENTER
to confirm. Use the UP and DOWN buttons to select:
BLACKOUT – If data connection is lost, fixture will blackout
HOLD – If data connection is lost, fixture holds latest received data value at all channels
Press ENTER to confirm.
Cooling Mode
This option sets whether the cooling fans run at full speed all the time, or will be controlled by
fixture output power.
To set cooling mode, select COOLING MODE from the PERSONALITY menu
and press ENTER
to confirm. Use the UP and DOWN buttons to select:
REGULATED FAN – Fan speed will be controlled by heat demand in the fixture.
FULL – Fans set to full constant speed.
Press ENTER to confirm.
Display
This option allows you to set some parameters for the display screen.
Select DISPLAY from the PERSONALITY meny and press ENTER to confirm.
Use the UP and DOWN buttons to select:
•
DISPLAY ROTATION – Use the UP and DOWN buttons to select Normal (Display
orientation normal) or ROTATE 180 (Display orientation rotated 180°)
•
DISPLAY INTENSITY – Use the UP and DOWN buttons to adjust display intensity from
10%-100% (default = 100%)
•
TEMPERATURE UNIT – Use the UP and DOWN buttons to select
°
C or
°
F