Installation
9
Surface mounting
The Cyclo 03 Directional can be
surface-mounted on a floor, wall or
ceiling using a bracket kit that is
available as an accessory.
To surface-mount the Cyclo 03
Directional:
1. Ensure that the surface on which
you want to mount the Cyclo 03
Directional can support the
weight of all the luminaires
installed on it.
2. Mark up two points 1100mm
(43.3 in.) apart as center points
for the mounting brackets. Allow
enough space around the center
points for the 110mm (4.3 in.)
square cover plates
3. Hold each mounting bracket against the mounting surface so that the
raised ridge in the bracket runs at 90° to the long side of the Cyclo 03
Directional (see illustrations), and so that the center point you have
marked is visible in the middle of the rectangular hole in the center of the
bracket.
4. Mark the mounting surface using the holes at the corners of each bracket
as guides, and drill holes in the mounting surface for the fasteners.
5. Fasten the mounting brackets to the surface using eight high-tensile
(grade 8.8 or over) M5 fasteners (screws, masonry bolts, etc.). Note that
the ridge in the bracket must be at 90° to the long side of the luminaire.
1100
Ø5.5
80
80
110
110
COVER
BRACKET