Installation
13
To create the data link:
1. Use suitable cable to connect one of the RJ-45 sockets on the first Cyclo
03 Directional to an RJ-45 socket on the next luminaire.
2. Continue connecting up to 32 luminaires using the RJ-45 sockets.
3. Terminate the link by inserting a an RJ-45 DMX termination plug (P/N
91613028) in the RJ-45 data output of the last luminaire.
4. If using a DMX control device, use suitable cable to connect the device’s
DMX output to one of the RJ-45 sockets on the first Cyclo 03 Directional.
TIp!
Random “flicker” and other unexplained control problems
during stand-alone master/slave operation can often be cured
by inserting an RJ-45 DMX termination plug into the unused
socket of the first luminaire.
Burning in fluorescent tubes
Optimum tube performance is obtained after burning in new fluorescent
tubes for 100 hours at full power.