Basic service
29
with a slow circular motion from center to edge. Dry with a clean, soft
and lint-free cloth or compressed air.
6. Replace the fixture cover (and lamp-access cover) before applying
power.
L A M P M A I N T E N A N C E
The Wizard Extreme is supplied installed with a Philips MSD 250/2 long-
life discharge lamp (average life 3000 hours). Lamp envelopes weaken
with age, so to reduce the risk of lamp explosion we recommend
replacement of this lamp after maximum 3300 hours of use, as specified
by the manufacturer.
The following lamp types are supported:
• Philips MSD 250/2
• Osram HSD 250
• Philips MSD 200
Important! Installing any other lamp may damage the fixture.
Allow the lamp to cool for at least 5 minutes before packing and moving
the fixture. To avoid possible damage, remove the lamp when shipping
the fixture.
Warning!
Always disconnect the fixture from AC power and allow it to
cool for at least 5 minutes before installing the lamp. The
screws on the lamp plate can reach 90° C (194° F) during
operation.
I n s t a l l i n g a l a m p i n t h e W i z a r d E x t r e m e
1. Disconnect the fixture from AC power. If
replacing a lamp, allow it to cool for at least
5 minutes before removing the lamp-access
cover. The lamp cools faster with the cover
in place. It can take up to 15 minutes for the
fixture to cool completely.
2. Remove the two lamp access screws from
the lamp-access cover, and lift the cover off.