C o n n e c t i n g t h e d a t a l i n k
1. Connect a data cable to the controller’s output. If controller has a 5-pin
output, use a 5-pin male to 3-pin female adaptor cable (P/N
11820005).
2. Lead the data cable from the controller to the first fixture. Plug the
cable into the fixture’s data input.
3. Connect the output of the fixture closest to the controller to the input of
the next fixture. If connecting two fixtures with opposing polarity on
pins 2 and 3, insert a phase-reversing cable between the two fixtures.
4. Continue connecting fixtures output to input. Up to 32 devices may be
connected on a serial link.
5. Terminate the link by inserting a male termination plug (P/N 91613017)
into the data output of the last fixture. A termination plug is simply an
XLR connector with a 120 ohm, 0.25 W resistor soldered across pins 2
and 3.
Male XLR
1
2
3
Male
P/N 91613017
120 Ohm
Female XLR
1
2
3
Female
120 Ohm
Termination Plug
Termination Plug
P/N 91613018