10
Wizard Extreme user manual
U S m o d e l
1. Disconnect the fixture from AC power.
2. If the lamp is hot, allow it to cool for 5 minutes and wear safety goggles
to protect your eyes.
3. Remove the six cover-access screws (see diagram inside the cover of
this manual) and lift off the fixture cover.
4. On the
ballast
, move the BLUE wire to the 225 V / 50 Hz terminal for
50 Hz local AC supply, or to the 225 V / 60 Hz terminal for 60 Hz local
AC supply.
5. On the
transformer
, move the BROWN wire to the setting as listed in
the previous table for the local AC voltage. The terminals are indicated
on a label on the top of the transformer.
6. Replace the cover.
Local
AC Voltage
Transformer taps
95 - 110 V
Blue wire: 20V
Brown wire: 120 V
110 - 130 V
Blue wire: 0 V
Brown wire: 120 V
200 - 220 V
Blue wire: 20 V
Brown wire: 230 V
220 - 240 V
Blue wire: 0 V
Brown wire: 230 V
240 - 260 V
Blue wire: 0 V
Brown wire: 250 V
Transformer
Ballast
225 V / 60 Hz
225 V / 50 Hz
250 V
230 V
120 V
20 V
0 V